Maxon np1 burner.
Burner, product number 461270.
- Maxon np1 burner. This industrial burner provides improved emissions performance over other gas burners with significantly lower levels of CO and NO2. 6-12 for the complete burner assembly to the “Net Free Area” of the duct: Burner part NP1-LE NP1-LE AL NP1-LE ALSS NP2-LE NP2-LE AL 1 Burner body Cast iron Aluminum Aluminum Cast iron Aluminum NP-I and NP-II AIRFLO® burner types provide a nominal capacity of 150 kW per foot. Its single-piece, seamless body design Find Maxon burners documentation at Relevant Industrial. The entire burner assembly is mounted directly in the air stream being heated. MAXON Series "NP" and "RG" AIRFLO® Industrial Burners provide clean, direct fired air heating to optimize process air heating efficiency. Burner, Maxon, 12 Inch, Np-Le, Product # 461270 Be the first to write a To determine the profile opening area, add the burner displacement area (cm2/section) from table on page 4-21. Downst ream temperatures should be limited to 1000°F. the burner. com LV-NP1 AIRFLO® burner with its gray iron body and #321 stainless steel mixing plates is the most economical choice for a raw gas burner system for fresh air heating with low heat release per lineal foot and outlet temperatures up to 1000°F. Optimum air stream velocity is 3000 ft/min. Greenheck is your source for tempered air product parts. 2020: EAC Zertifikat Linien- und Kanalbrenner für die Lufterwärmung RatioStar, Minnox, Linnox, FlueFire, Combustifume, Crossfire, HC Airflo,NP-LE Airflo, NP-RG Airflo, Linoflame, APX (RU) The Honeywell Maxon's NP-LE (low emissions) AIRFLO® natural gas burner is designed for direct-fired make-up air and process applications. MAXON APX ™ burners are packaged nozzle-mix line burners, especially designed for fresh or low temperature recirculating air heating applications. NP-II AIRFLO® burners will Brand Name: Honeywell Maxon Alt Part #: NP1LE Airflow Line burner Sales Proposal # 262894 For fresh, ambient air heating, the NP1-LE and NP2-LE AIRFLO® burner types provide a nominal capacity of 1. 5 MBtu/h per foot would have an approximate flame length of 10 in. Optimum air stream velocity is 15 m (st)/s. Contact MAXON for operation out side the optimum operation area. Maxon Series "NP" and "RG" AIRFLO®Burners consist of rust-resistant cast iron bodies (which serve as the gas manifold) drilled to discharge the fuel between diverging stainless steel mixing plates. Series NP-LE AIRFLO® burners are designed for direct heating of fresh, clean air for low and medium temperature air heating applications NP-I and NP-II AIRFLO® burner types provide a nominal capacity of 0. Improved emissions performance over MAXON’s standard “NP” AIRFLO® Burner, with significantly lower levels of CO and NO2; High capacity – up to 1,000,000 Btu/h/ft; Short flame length; Available in low pressure version and corrosion-resistant materials See full list on marshallwnelson. EXAMPLE: Series NP-I AIRFLO ® burner at 3000 sfpm and at 0. Burner NP1-LE and NP2-LE 1-1/4” end inlet flange equal to or less than 4 ft MAXON Series NP-RG AIRFLO® Industrial Burners provide clean, direct fired air heating to optimize process air heating efficiency. With staged burner configuration turndown may exceed 50 : 1. NP2-LE AIRFLO® burners are selected when gas supply pressures are too low for NP1-LE burners. 858. 01. Enjoy same-day, free shipping on in-stock products over $25 For fresh, ambient air heating, the NP1-LE and NP2-LE AIRFLO® burner types provide a nominal capacity of 1. The modular natural gas burners install easily with custom built patterns to fit your duct. Upstream process air temperatures should not exceed 600°F. Always avoid rigid mounting. NP and RG burners burn cleanly with most gaseous fuels and offer high heat releases per foot with wide turndown ratios. For process air heating NP1-LE and NP2-LE AIRFLO ® burners may be used if temperature rise does not exceed 760°F . Contact MAXON for operation outside th e optimum operation area (shaded area). Airstream velocity across and through the burner’s mixing plates must be kept uniform and within de sired limits by use of a. NP1-LE and NP2-LE Size Edition Date Details; Assembly Pages NP-LE AIRFLO® Burners (EN) Spare part list: 114kB: 04. NP-II AIRFLO® burners are selected when gas supply pressure is too low for NP-I AIRFLO® burners. Turndown of 25 : 1. 5 MBtu/h per foot. 5-AP-1 9/15 Assembly Numbers Approximate net ship weight (in pounds) shown in parentheses Series NP/RG AIRFLO ® Burners - cast iron bodies Burner Type NP-I The MAXON NP-LE EMISSIONS AIRFLO® Natural Gas Burner is designed for direct-fired make-up air and process applications. 3647 1. FOR PROCESS AIR HEATING NP1-LE and NP2-LE AIRFLO® burners may be used if aluminum body, 430ss mixing plate, ansi threaded connection, 450-460 max approach air temp, (1) 6” str sect, (3) 12” str sect, with spark ignitor, flame rods, & covers, adjustable orifice, support brackets and flange fastening kits NP2-LE AIRFLO ® burners are selected when gas supply pressures are too low for NP1-LE burners. The APX ™ burner is a value engineered design utilizing a single aluminum extrusion for both its main air and fuel manifolds. 1. 0 MBtu/h per foot with a turndown of 30:1. For process air heating NP1-LE and NP2-LE AIRFLO ® burners may be used if temperature rise does not exceed 400°C. Burner, product number 461270. If there are multiple inlets, you must avoid rigid connection by using the oversize U-bolt (loosely drawn up) illustrated. FOR PROCESS AIR HEATING NP1-LE and NP2-LE AIRFLO® burners may be used if Maxon reserves the right to alter specifications and data without prior notice. It reserves the right to alter specifications without prior notice. Reliable resources for efficient combustion system performance. Sketch 6 shows Maxon USB support brackets suspending the Honeywell Maxon's full line of industrial burners and combustion equipment includes gas burners, oil burners, gas valves, shut off valves, flow control valves, and low NOx burners. 858 forward movement of the burner. NP1-LE and NP2-LE Burner Assembly, product number 452858. 888. Airstream velocity across and through the burner’s mixing plates must be kept uniform and within desired limits by use of a NP2-LE AIRFLO ® burners are selected when gas supply pressures are too low for NP1-LE burners. Upstream process air temperatures should not exceed 315°C. Maxon products are designed to blend durable, reliable products with the best technologies to provide clean, safe, and efficient heat to help make your operation Maxon practices a policy of continuous product improvement. For upstream process air temperature up to 600°F. 6-12 for the complete burner assembly to the “Net Free Area” of the duct: Burner part NP1-LE NP1-LE AL NP1-LE ALSS NP2-LE NP2-LE AL 1 Burner body Cast iron Aluminum Aluminum Cast iron Aluminum Honeywell 7800 SERIES burner control unit; Kromschroeder IFD 258 burner control unit; Kromschroeder IFD 244 burner control unit; Burner control units BCU 560, BCU 565, BCU 580; Automatic burner control units PFU; Burner control unit BCU 570; Honeywell SLATE combustion management system; Protective system control FCU; SOLA; Legacy Burner Honeywell 7800 SERIES burner control unit; Kromschroeder IFD 258 burner control unit; Kromschroeder IFD 244 burner control unit; Burner control units BCU 560, BCU 565, BCU 580; Automatic burner control units PFU; Burner control unit BCU 570; Honeywell SLATE combustion management system; Protective system control FCU; SOLA; Legacy Burner EXAMPLE: Series NP-III AIRFLO ® burner at 4000 sfpm and 1 MBtu per foot would have an approximate flame length of 30 in. NP-II AIRFLO® burners will NP1LEAL-A450 6FT Q#25269530,NP1LEAL-A450 6FT Q#25269530,Honeywell Maxon,,NP-1-LE-AL Line Burner 6FT Straight Sect,Stromquist & Company To determine the profile opening area, add the burner displacement area (cm2/section) from table on page 4-21. MAXON Series NP-LE AIRFLO ® burners are especially designed to meet the high demands of most of the local standards on air quality of direct fired make-up air and space heating applications worldwide. 16: 30. Maxon Series NP and RG burners provide clean, direct fired air heating to optimize process air heating efficiency. Series “NP” & “RG” AIRFLO® Line Burners Page 4-21. Support for down-fired burners can be accomplished as shown in the illustration at right. Downstream temperatures should be limited to 540°C.
etsmwg mqf egz pcwey ypgk xta gulbmnh twcwaao nti rcaho